Catalogue

Filter By

Application on glazing

Application on glazing

Adhesive type

Adhesive type

Optical property

Optical property

Glare problem

Glare problem

Heat problem in summer

Heat problem in summer

Thermal insulation in winter

Thermal insulation in winter

Solar heat gain in winter

Solar heat gain in winter

Limit fading

Limit fading

Professional athermal adhesive film for windows

Thermal insulation of glazing and protection against solar radiation



Set of thermal regulation adhesive film to fight against excessive solar heat input, reduce heat loss or limit damage caused by UV or IR radiation.

Active filters

  • Glare problem: Low
  • Glare problem: Significant
  • Heat problem in summer: Average (+6°C)
  • Heat problem in summer: Low (+4°C)

Infrared absorber Neutral 70

IR 70 IN NRN HPRA

Absorber IR 70

  • Category : IR absorber
  • Type : Not reflective
  • Shades : Light blue-green
  • % Light transmission : 78%
  • % Light reflection - outside : 8%
  • % Total solar energy rejected : 36%

Low emissivity neutral medium

kryo 20N IN SR CDA

Kryo 20 N

  • Category : 4 seasons
  • Type : Semi-reflective
  • Shades : Neutral bronze
  • % Light transmission : 28%
  • % Light reflection - outside : 36%
  • % Total solar energy rejected : 73%
  • Emissivity : 0,32

Infrared absorber Blue 80

IR 80 IN NRB HPRA

Absorber IR 80

  • Category : IR absorber
  • Type : Not reflective
  • Shades : Bluish clear
  • % Light transmission : 78%
  • % Light reflection - outside : 8%
  • % Total solar energy rejected : 44%

Neutral sputtered light

umbra 50 IN NRT CDA

Umbra 50

  • Category : Solar
  • Type : Not reflective
  • Shades : Tinted
  • % Light transmission : 49%
  • % Light reflection - outside : 13%
  • % Total solar energy rejected : 45%

Spectral selector 60

lumen 60 IN NRC CDA

Lumen 60

  • Category : Solar
  • Type : Not reflective
  • Shades : Blue/Green light
  • % Light transmission : 66%
  • % Light reflection - outside : 9%
  • % Total solar energy rejected : 55%

Bronze sputtered dark

ilios 20B IN SR CDA

ilios 20 B

  • Category : Solar
  • Type : Semi-reflective
  • Shades : Bronze
  • % Light transmission : 21%
  • % Light reflection - outside : 36%
  • % Total solar energy rejected : 78%

Neutral sputtered very light

umbra 65 IN NRT CDA

Umbra 65

  • Category : Solar
  • Type : Not reflective
  • Shades : Tinted
  • % Light transmission : 68%
  • % Light reflection - outside : 9%
  • % Total solar energy rejected : 30%

EX - Infrared absorber Blue 80

IR 80 EX NRB HPRA

EX - Absorber IR 80

  • Category : IR absorber
  • Type : Not reflective
  • Shades : Bluish clear
  • % Light transmission : 78%
  • % Light reflection - outside : 8%
  • % Total solar energy rejected : 44%

Spectral selector 70

lumen 70 IN NRC CDA

Lumen 70

  • Category : Solar
  • Type : Not reflective
  • Shades : Neutral green light
  • % Light transmission : 69%
  • % Light reflection - outside : 8%
  • % Total solar energy rejected : 52%

EX - Spectral selector 70

lumen 70 EX NRC HPRA

EX - Lumen 70

  • Category : Solar
  • Type : Not reflective
  • Shades : Neutral green light
  • % Light transmission : 68%
  • % Light reflection - outside : 9%
  • % Total solar energy rejected : 56%