Demonstration Video
IR rejection test under controlled environment
The infrared lamp (75W) heats two steel plates connected to a thermometer, the whole being placed behind a glass plate (4mm).
The adhesive film presented on this page is stuck on the right side.
Actual test duration: 30 min
If the message "This video is not available" appears, refresh the page to see the video.
Data sheet
Simple glazing clear glass 4mm | Double glazing clear glass 4/16/4mm | |
---|---|---|
Optical property | Not reflective | |
Shades (out/in) | Blue/Green light | |
Face of application on glazing | Inside | |
Adhesive type | CDA | |
% Light Transmission | 66 | 60 |
% Glare reduction | 27 | 27 |
% Light reflection (out/in) | 9/10 | 16/13 |
Emissivity value | 0.60 | |
Winter value U (W/m²°K) | 5.06 | 2.54 |
Value of solar g factor | 0.45 | 0.54 |
Shading coefficient | 0.52 | 0.62 |
% Transmission of solar energy | 38 | 34 |
% Reflection of solar energy | 26 | 27 |
% Absorption of solar energy | 36 | 39 |
% Total solar energy rejected | 55 | 46 |
% UV Transmission | < 1 | |
Colour Rendering Index | 96 | 95 |
Film thickness (µm) | 50 | |
Limited warranty (years) | 10 |
Compatibility on glazing
lumen 60 IN NRC CDA | |
---|---|
- Preapproved | - Recommended study | - Not approved | |
Single glazing Clear or tinted |
|
Double glazing Clear or tinted |
|
Double glazing Clear Low-E #2 |
|
Double glazing Clear Low-E #3 |
Data sheet
Type of medium | Glass |
Application on glazing | Interior |
Adhesive type | CDA |
Optical property | Not reflective |
Visibility | Transparent |
Glare problem | Low |
Heat problem in summer | Average (+6°C) |
Thermal insulation in winter | No - Not necessary |
Solar heat gain in winter | Yes - Keep |
Limit fading | UV + IR + Light |