Data sheet
Simple glazing clear glass 4mm | Double glazing clear glass 4/16/4mm | |
---|---|---|
Optical property | Not reflective | |
Shades (out/in) | Neutral green light | |
Face of application on glazing | Inside | |
Adhesive type | CDA | |
% Light Transmission | 69 | 63 |
% Glare reduction | 23 | 23 |
% Light reflection (out/in) | 8/7 | 14/11 |
Emissivity value | 0.59 | |
Winter value U (W/m²°K) | 5.05 | 2.54 |
Value of solar g factor | 0.48 | 0.56 |
Shading coefficient | 0.55 | 0.64 |
% Transmission of solar energy | 40 | 36 |
% Reflection of solar energy | 24 | 26 |
% Absorption of solar energy | 36 | 38 |
% Total solar energy rejected | 52 | 44 |
% UV Transmission | < 1 | |
Colour Rendering Index | 97 | 96 |
Film thickness (µm) | 50 | |
Limited warranty (years) | 10 |
Compatibility on glazing
lumen 70 IN NRC CDA | |
---|---|
- Preapproved | - Recommended study | - Not approved | |
Single glazing Clear or tinted |
|
Double glazing Clear or tinted |
|
Double glazing Clear Low-E #2 |
|
Double glazing Clear Low-E #3 |
Data sheet
Type of medium | Glass |
Application on glazing | Interior |
Adhesive type | CDA |
Optical property | Not reflective |
Visibility | Transparent |
Glare problem | Low |
Heat problem in summer | Average (+6°C) |
Thermal insulation in winter | No - Not necessary |
Solar heat gain in winter | Yes - Keep |
Limit fading | UV + IR + Light |