Demonstration Video
IR rejection test under controlled environment
The infrared lamp (75W) heats two steel plates connected to a thermometer, the whole being placed behind a glass plate (4mm).
The adhesive film presented on this page is stuck on the right side.
Actual test duration: 30 min
If the message "This video is not available" appears, refresh the page to see the video.
Data sheet
Simple glazing clear glass 4mm | Double glazing clear glass 4/16/4mm | |
---|---|---|
Optical property | Low reflective | |
Shades (out/in) | Bronze | |
Face of application on glazing | Inside | |
Adhesive type | CDA | |
% Light Transmission | 37 | 34 |
% Glare reduction | 59 | 59 |
% Light reflection (out/in) | 25/22 | 29/24 |
Emissivity value | 0.68 | |
Winter value U (W/m²°K) | 5.31 | 2.60 |
Value of solar g factor | 0.34 | 0.45 |
Shading coefficient | 0.39 | 0.52 |
% Transmission of solar energy | 26 | 24 |
% Reflection of solar energy | 36 | 35 |
% Absorption of solar energy | 38 | 41 |
% Total solar energy rejected | 66 | 55 |
% UV Transmission | < 1 | |
Colour Rendering Index | 93 | 94 |
Film thickness (µm) | 50 | |
Limited warranty (years) | 7 |
Compatibility on glazing
ilios 35B IN PR CDA | |
---|---|
- Preapproved | - Recommended study | - Not approved | |
Single glazing Clear or tinted |
|
Double glazing Clear or tinted |
|
Double glazing Clear Low-E #2 |
|
Double glazing Clear Low-E #3 |
Data sheet
Type of medium | Glass |
Application on glazing | Interior |
Adhesive type | CDA |
Optical property | Low reflective |
Visibility | Transparent |
Glare problem | Average |
Heat problem in summer | Average (+6°C) |
Thermal insulation in winter | No - Not necessary |
Solar heat gain in winter | Yes - Keep |
Limit fading | UV + IR + Light |