Demonstration Video
IR rejection test under controlled environment
The infrared lamp (75W) heats two steel plates connected to a thermometer, the whole being placed behind a glass plate (4mm).
The adhesive film presented on this page is stuck on the right side.
Actual test duration: 30 min
If the message "This video is not available" appears, refresh the page to see the video.
Data sheet
| Simple glazing clear glass 4mm | Double glazing clear glass 4/16/4mm | |
|---|---|---|
| Optical property | Reflective | |
| Shades (out/in) | Silver / Bluish | |
| Face of application on glazing | Outside | |
| Adhesive type | HPRA | |
| % Light Transmission | 16 | 15 |
| % Glare reduction | 82 | 82 |
| % Light reflection (out/in) | 62/60 | 62/59 |
| Emissivity value | 0.74 | |
| Winter value U (W/m²°K) | 5.70 | 2.69 |
| Value of solar g factor | 0.19 | 0.15 |
| Shading coefficient | 0.22 | 0.17 |
| % Transmission of solar energy | 12 | 11 |
| % Reflection of solar energy | 60 | 60 |
| % Absorption of solar energy | 28 | 29 |
| % Total solar energy rejected | 81 | 85 |
| % UV Transmission | < 1 | |
| Colour Rendering Index | 85 | 85 |
| Film thickness (µm) | 90 | |
| Limited warranty (years) | 10 | |
Compatibility on glazing
| ilios 20A EX R HPRA | |
|---|---|
| - Preapproved | - Recommended study | - Not approved | |
| Single glazing Clear or tinted |
|
| Double glazing Clear or tinted |
|
| Double glazing Clear Low-E #2 |
|
| Double glazing Clear Low-E #3 |
|
Data sheet
| Type of medium | Glass |
| Application on glazing | Exterior |
| Adhesive type | HPRA |
| Optical property | Reflective |
| Visibility | Transparent |
| Glare problem | Significant |
| Heat problem in summer | Excessive (up 8°C) |
| Thermal insulation in winter | No - Not necessary |
| Solar heat gain in winter | No - Not necessary |
| Limit fading | UV + IR + Light |