18.37 € / m²
A nice reflective bronze shade for great protection against excessive solar heat and glare.
Demonstration Video
IR rejection test under controlled environment
The infrared lamp (75W) heats two steel plates connected to a thermometer, the whole being placed behind a glass plate (4mm).
The adhesive film presented on this page is stuck on the right side.
Actual test duration: 30 min
Data sheet
Simple glazing clear glass 4mm | Double glazing clear glass 4/16/4mm | |
---|---|---|
Optical property | Semi-reflective | |
Shades (out/in) | Bronze | |
Face of application on glazing | Inside | |
Adhesive type | CDA | |
% Light Transmission | 21 | 20 |
% Glare reduction | 77 | 76 |
% Light reflection (out/in) | 36/33 | 38/33 |
Emissivity value | 0.58 | |
Winter value U (W/m²°K) | 5.00 | 2.52 |
Value of solar g factor | 0.22 | 0.35 |
Shading coefficient | 0.25 | 0.40 |
% Transmission of solar energy | 14 | 13 |
% Reflection of solar energy | 46 | 43 |
% Absorption of solar energy | 40 | 44 |
% Total solar energy rejected | 78 | 65 |
% UV Transmission | < 1 | |
Colour Rendering Index | 93 | 94 |
Film thickness (µm) | 50 | |
Limited warranty (years) | 7 |
Compatibility on glazing
ilios 20B IN SR CDA | |
---|---|
- Preapproved | - Recommended study | - Not approved | |
Single glazing Clear or tinted |
|
Double glazing Clear or tinted |
|
Double glazing Clear Low-E #2 |
|
Double glazing Clear Low-E #3 |
Data sheet
Type of support | Glass |
Glass application | Interior |
Visibility and opposite | Semi-reflective |
Glare problem | Important |
Heat problem in summer | Medium (+6°C) |
Thermal insulation in winter | No - Not necessary |
Provides solar heat in winter | No - Not necessary |
Limit fading | UV+IR+Light (Tinted) |